Power supplies - Large capacity P.S
ODM/OEM If you can not find a suitable model, please contact us regarding a customized adapter to meet your requirement.
S-1000-85 (Large Capacity P.S)
Special Feature Input voltage 88 ~ 132VAC/176 ~ 264 VAC BY SWITCH Input frequency 47 ~ 63Hz Inrush current cold start,30A/115VAC,60A/230VAC Output voltage 85VDC Output current 0- 11A Ripple & Noise 300mv Output voltage liner regulation < 10% EFFI 86% Output voltage load regulation +/- 0.5% Output power 1000W Over load protection 105% ~ 130% output shutdown Over voltage protection 115% ~ 150% of output voltage Setup, rise£¬hold up time 200ms, 50ms 20ms at full load Withstand voltage I/P-O/P:3KV;I/P-FG:1.5KV;1min Working temp 0-50° @ 100%, -10° @ 80%, +80° @80% Safety standard To meet TUV EN60950 , CE EMC standard Design refer to EN55022 class B,EN61000-3-2,3,5-3 Env50204 Cooling method Fan Dimension 320x180x120mm Weight 4.8kgs/pcs
S-1800-24 (Large Capacity P.S)
Special Feature Input voltage 200-240VAC Input frequency 47 ~ 63Hz Inrush current cold start,30A/115VAC,60A/230VAC Input current 14A/230VAC Output voltage 24VDC Output current 0- 75A Ripple& Noise 300mv Output voltage liner regulation < 10% EFFI 80% Output voltage load regulation +/- 0.5% Output power 1800W Over load protection 105% ~ 130% output shutdown Over voltage protection 115% ~ 150% of output voltage Setup, rise£¬hold up time 200ms, 50ms 20ms at full load Withstand voltage I/P-O/P:3KV;I/P-FG:1.5KV;1min Working temp -0-50° @ 100%, -10° @80%, +80 @ 80% Safety standard To meet TUV EN60950 , CE EMC standard Design refer to EN55022 class Cooling method Fan Dimension 291x132x132mm Weight 3.5kgs/pcs
Note: Input EMI filter Protections: Short circuit/over load/over current/over voltage/over temperature Built-in remote sense function 100% full load burn-in test
S-2500-24 (Large Capacity P.S)
Special Feature Input voltage 200-240VAC Input frequency 47 ~ 63Hz Inrush current cold start, 60A/230VAC Output voltage 24VDC Output current 100A Current Leakage 3.5ma(Max) Linear regulation < 1% Load regulation < 2% Ripple& Noise 150mv Range of Output voltage < 5% EFFI 85% Output power 2500W Over load protection 110% ~ 130% output shutdown Over voltage protection 115% ~ 135% of output voltage Setup, rise£¬hold up time 800ms, 400ms 12ms at full load 230V Withstand voltage I/P-O/P:3KV;I/P-FG:1.5KV;1min Working -10° ~+40° @ 100% LOAD +60° @ 50% LOAD Safety standard To meet TUV EN60950 , CE EMC standard Design refer to EN55022 class Dimension 320 < 132 < 134mm Weight 10Kg s/pcs
Note: Input EMI filter Protections: Short circuit/over load/over current/over voltage/over temperature Built-in remote sense function/Built ¨Cin remote ON/OFF control 100% full load burn-in test Parallel(N+1) Can adjust from 20-100% output voltage by external control 1-5VDC.
|